Stationary Constant Potential Industrial X-ray machine

Stationary Constant Potential Industrial X-ray machine
Product Detailed
Related Categories:Testing Equipment
1.Stationary Constant Potential Industrial X-ray machine 2.Stationary X-ray machine 3.Constant potential X-ray machine

Stationary Constant Potential Industrial X-ray machine

XYG-22510/3 model

1. The system configuration list:

No.

name

Description

quantity

manufacturer

remark

1

metal ceramic X-ray tube

MXR-225/22

1nos

COMET

Unipolar,directional

With quick-lock cable flange

2

High voltage cable

225KV

1nos

COMET

225KV,5mlong

3

High Voltage Generator

H225

1nos

AOLONG

Including 10 meters power cable

4

Controller

T7000

1nos

AOLONG

Including 10meters connecting control cable

5

Water cooler

ZLB-4

1nos

AOLONG

Including 10 meters cooling water tube,2pcs

6

Support vehicle

225KV

1set

AOLONG

Used to x-ray tube moving and fixing

7

appropriative Accessory 

 

1set

AOLONG

Including signal cable,jumper(door),alarm lamp,grounding cable, fuse,Silicon paste etc 

8

Spare part and tools

 

1set

AOLONG

Included Lead intensify screen, Dark bag, Image quality indicate, Lead letter 

2.Technical specification

2.1 XYG-22510/3 model industrial x-ray machine main technology parameter

 Tube voltage: 20~225KV, adjust constantly and the step is 0.1Kv

Tube current:When 225KV, Tube current: 0.1~10mA(big focus)  0.1~2.8mA(small focus)Adjust constantly and the step is 0.1 mA

Sensitivity: ≤ 1.5%

Film density: >2.0

The Max Maximal penetration (Fe):45mm

Exposure condition:

Tube voltage: 225KV  

Exposure gross: 100mA•min

Double foil lead intensifying screen

Focus distance: 600mm

Developing temperature: 20°C

      Industrial X-ray film

2.2Unipolar metal ceramic X-ray tube (directional)

model:MXR-225/22

Original Area:COMET, Switzerland

Max tube voltage:225kv

Continuous rating: 640W/3000W

Focal spot:d=1.0mm(small focus)/d =5.5mm(big focus)(EN12543)

Filament current,max:4.1A / 4.2A

Filament voltage, typical:3.0V/5.5 V

Inherent Filtration:0.8mm Be

Target metrial:W

Target angle:20°

 Radiation coverage: 40°

Leakage radiation, max.:10 mSv/h

Cooling medium: water

Cooling medium flow, min.:4l/min

Temperature at inlet, Max.:35°C

Weight:11Kg

Terminal type: R24

2.3 High voltage cable

Standard load:225KV

Length:5 meters long

Is used to Connect X-ray tube and generator;

Connection fashion: flange

2.4High Voltage generator

Duty cycle:100% work continuously

X-ray flaw detector frequency:40KHz

Input

Voltage:220VAC±10% 

Frequency:50Hz±2%

 Output

 Max.output Voltage: 225KV

 Max.output current: 45mA

 Max.output power: 3000W

 Tube Voltage: from 5KV to 225KV in 0.1KV increment

Display resolution: 0.1KV

Accuracy:±1%

Tube current: from 0.1mA to 45mA in 0.1mA increment

Display resolution:0.1mA

Accuracy:±1%

High Voltage ripple:6V/mA

Employment temperature:5~40°C  Employment humidity:≤85%

Insulation mode: oil

Remark: High voltage and current of X-ray tube have super precision and stability due to the high frequency high voltage technologies been adopted,High frequency technology shorten on-off time, redound to shorten inspect cycle, improve work efficiency. 40KHz mainframe frequency is the advanced technical standard in the international calling, Supernal dependability of continuous work, long employ life, low failure ratio.

2.5Controller

Parameter:

Controller screen displays current working parameters in digital mode, and all function parameters displayed on it can inter-lock diagnostic result.

The controller makes alarm in sound and light signals when the high voltage on and off. It also has the functions of safe interlock protect and alarm when water and electric conditions are not satisfied or in case wrong operations.