- Contact Person : Mr. Feng Charles
- Company Name : Dandong Aolong Radiative Instrument Co., Ltd.
- Tel : 86-415-3458128
- Fax : 86-415-3458588
- Address : Liaoning,DANDONG,NO.46,FUMIN STREET,LINGANG HIGH-TECH ZONE,DANDONG CITY,CN
- Country/Region : China
- Zip : 118009
Stationary Constant Potential Industrial X-ray machine
Stationary Constant Potential Industrial X-ray machine
XYG-22510/3 model
1. The system configuration list:
No. | name | Description | quantity | manufacturer | remark |
1 | metal ceramic X-ray tube | MXR-225/22 | 1nos | COMET | Unipolar,directional With quick-lock cable flange |
2 | High voltage cable | 225KV | 1nos | COMET | 225KV,5mlong |
3 | High Voltage Generator | H225 | 1nos | AOLONG | Including 10 meters power cable |
4 | Controller | T7000 | 1nos | AOLONG | Including 10meters connecting control cable |
5 | Water cooler | ZLB-4 | 1nos | AOLONG | Including 10 meters cooling water tube,2pcs |
6 | Support vehicle | 225KV | 1set | AOLONG | Used to x-ray tube moving and fixing |
7 | appropriative Accessory |
| 1set | AOLONG | Including signal cable,jumper(door),alarm lamp,grounding cable, fuse,Silicon paste etc |
8 | Spare part and tools |
| 1set | AOLONG | Included Lead intensify screen, Dark bag, Image quality indicate, Lead letter |
2.Technical specification
2.1 XYG-22510/3 model industrial x-ray machine main technology parameter
Tube voltage: 20~225KV, adjust constantly and the step is 0.1Kv
Tube current:When 225KV, Tube current: 0.1~10mA(big focus) 0.1~2.8mA(small focus)Adjust constantly and the step is 0.1 mA
Sensitivity: ≤ 1.5%
Film density: >2.0
The Max Maximal penetration (Fe):45mm
Exposure condition:
Tube voltage: 225KV
Exposure gross: 100mA•min
Double foil lead intensifying screen
Focus distance: 600mm
Developing temperature: 20°C
Industrial X-ray film
2.2Unipolar metal ceramic X-ray tube (directional)
model:MXR-225/22
Original Area:COMET, Switzerland
Max tube voltage:225kv
Continuous rating: 640W/3000W
Focal spot:d=1.0mm(small focus)/d =5.5mm(big focus)(EN12543)
Filament current,max:4.1A / 4.2A
Filament voltage, typical:3.0V/5.5 V
Inherent Filtration:0.8mm Be
Target metrial:W
Target angle:20°
Radiation coverage: 40°
Leakage radiation, max.:10 mSv/h
Cooling medium: water
Cooling medium flow, min.:4l/min
Temperature at inlet, Max.:35°C
Weight:11Kg
Terminal type: R24
2.3 High voltage cable
Standard load:225KV
Length:5 meters long
Is used to Connect X-ray tube and generator;
Connection fashion: flange
2.4High Voltage generator
Duty cycle:100% work continuously
X-ray flaw detector frequency:40KHz
Input
Voltage:220VAC±10%
Frequency:50Hz±2%
Output
Max.output Voltage: 225KV
Max.output current: 45mA
Max.output power: 3000W
Tube Voltage: from 5KV to 225KV in 0.1KV increment
Display resolution: 0.1KV
Accuracy:±1%
Tube current: from 0.1mA to 45mA in 0.1mA increment
Display resolution:0.1mA
Accuracy:±1%
High Voltage ripple:6V/mA
Employment temperature:5~40°C Employment humidity:≤85%
Insulation mode: oil
Remark: High voltage and current of X-ray tube have super precision and stability due to the high frequency high voltage technologies been adopted,High frequency technology shorten on-off time, redound to shorten inspect cycle, improve work efficiency. 40KHz mainframe frequency is the advanced technical standard in the international calling, Supernal dependability of continuous work, long employ life, low failure ratio.
2.5Controller
Parameter:
Controller screen displays current working parameters in digital mode, and all function parameters displayed on it can inter-lock diagnostic result.
The controller makes alarm in sound and light signals when the high voltage on and off. It also has the functions of safe interlock protect and alarm when water and electric conditions are not satisfied or in case wrong operations.
Stationary Constant Potential Industrial X-ray machine